-d $(KDIR)/vmlinux-$(2).bin.lzma $(KDIR)/vmlinux-$(2).uImage; \
( \
dd if=$(KDIR)/vmlinux-$(2).uImage bs=1280k conv=sync; \
- dd if=$(KDIR)/root.$(1) bs=6336k conv=sync; \
- echo -n $(4); \
- ) > $(call imgname,$(1),$(2)).bin; \
- wrt400n $(KDIR)/vmlinux-$(2).uImage $(KDIR)/root.$(1) $(call imgname,$(1),$(2)).webui; \
+ dd if=$(KDIR)/root.$(1) \
+ ) > $(call imgname,$(1),$(2))-sysupgrade.bin; \
+ wrt400n $(KDIR)/vmlinux-$(2).uImage $(KDIR)/root.$(1) $(call imgname,$(1),$(2))-factory.bin; \
fi; fi
endef
dir825b1_mtdlayout=mtdparts=spi0.0:256k(uboot)ro,64k(config)ro,1024k(kernel),5184k(rootfs),64k(caldata)ro,1600k(unknown)ro,6208k@0x50000(firmware)
define Image/Build/DIR825B1
$(call PatchKernelLzma,$(2),$(3) $(dir825b1_mtdlayout))
- $(call MkImageLzma,$(KDIR)/vmlinux-$(2).bin.lzma,$(call imgname,$(1),$(2)).bin)
- if [ `stat -c%s "$(call imgname,$(1),$(2)).bin"` -gt 1048576 ]; then \
+ if [ `stat -c%s "$(KDIR)/vmlinux-$(2).bin.lzma"` -gt 1048576 ]; then \
echo "Warning: $(KDIR)/vmlinux-$(2).bin.lzma is too big"; \
- rm -f $(call imgname,$(1),$(2)).bin; \
else if [ `stat -c%s $(KDIR)/root.$(1)` -gt 5308416 ]; then \
echo "Warning: $(KDIR)/root.$(1) is too big"; \
- rm -f $(call imgname,$(1),$(2)).bin; \
else \
- dd if=$(KDIR)/root.$(1) of=$(call imgname,$(1),$(2)).bin bs=1k seek=1024; \
- cp $(call imgname,$(1),$(2)).bin $(call imgname,$(1),$(2))-backup-loader.bin; \
- echo -n "01AP94-AR7161-RT-080619-00" >> $(call imgname,$(1),$(2))-backup-loader.bin; \
+ mkimage -A mips -O linux -T kernel -a 0x80060000 -C lzma -e \
+ 0x80060000 \
+ -n 'MIPS OpenWrt Linux-$(LINUX_VERSION)' \
+ -d $(KDIR)/vmlinux-$(2).bin.lzma $(KDIR)/vmlinux-$(2).uImage; \
+ ( \
+ dd if=$(KDIR)/vmlinux-$(2).uImage bs=1024k conv=sync; \
+ dd if=$(KDIR)/root.$(1) \
+ ) > $(call imgname,$(1),$(2))-sysupgrade.bin; \
+ ( \
+ dd if=$(call imgname,$(1),$(2))-sysupgrade.bin; \
+ echo -n "01AP94-AR7161-RT-080619-00"; \
+ ) > $(call imgname,$(1),$(2))-backup-loader.bin; \
+ if [ `stat -c%s $(call imgname,$(1),$(2))-sysupgrade.bin` -gt 4194304 ]; then \
+ echo "Warning: $(call imgname,$(1),$(2))-sysupgrade.bin is too big"; \
+ else \
+ ( \
+ dd if=$(call imgname,$(1),$(2))-sysupgrade.bin bs=4096k conv=sync; \
+ echo -n "00AP94-AR7161-RT-080619-00"; \
+ ) > $(call imgname,$(1),$(2))-factory.bin; \
+ fi; \
fi; fi
endef
endef
define Image/Build/PB92
- $(call PatchKernelGzip,$(2),$(3))
- if [ `stat -c%s $(KDIR)/root.$(1)` -gt 2818048 ]; then \
+ $(call PatchKernelLzma,$(2),$(3))
+ if [ `stat -c%s $(KDIR)/vmlinux-$(2).bin.lzma` -gt 917504 ]; then \
+ echo "Warning: $(KDIR)/vmlinux-$(2).bin.lzma is too big"; \
+ elif [ `stat -c%s $(KDIR)/root.$(1)` -gt 2818048 ]; then \
echo "Warning: $(KDIR)/root.$(1) is too big"; \
else \
- mkimage -A mips -O linux -T kernel -a 0x80060000 -C gzip -e \
+ mkimage -A mips -O linux -T kernel -a 0x80060000 -C lzma -e \
0x80060000 \
-n 'MIPS OpenWrt Linux-$(LINUX_VERSION)' \
- -d $(KDIR)/vmlinux-$(2).bin.gz \
+ -d $(KDIR)/vmlinux-$(2).bin.lzma \
$(KDIR)/vmlinux-$(2).uImage; \
dd if=$(KDIR)/vmlinux-$(2).uImage \
of=$(call imgname,kernel,$(2)).bin bs=64k conv=sync; \
-d $(KDIR)/vmlinux-$(2).bin.gz $(KDIR)/vmlinux-$(2).uImage; \
( \
dd if=$(KDIR)/vmlinux-$(2).uImage bs=1408k conv=sync; \
- dd if=$(KDIR)/root.$(1) bs=6208k conv=sync; \
- ) > $(call imgname,$(1),$(2)).bin; \
+ dd if=$(KDIR)/root.$(1); \
+ ) > $(call imgname,$(1),$(2))-sysupgrade.bin; \
$(STAGING_DIR_HOST)/bin/mkplanexfw \
-B $(2) \
-v 2.00.00 \
- -i $(call imgname,$(1),$(2)).bin \
- -o $(call imgname,$(1),$(2)).webui; \
+ -i $(call imgname,$(1),$(2))-sysupgrade.bin \
+ -o $(call imgname,$(1),$(2))-factory.bin; \
fi; fi
endef